Shopping cart

Subtotal: $0.00

HCNR201-000E: High-Quality Opto-Isolator with 5kV Isolation Voltage by Broadcom

HCNR201-000E: Premium Opto-Isolator with 5kV Isolation by Broadcom

The HCNR201-000E represents the gold standard in opto-isolation technology, combining Broadcom's renowned engineering excellence with industry-leading 5kV isolation capabilities. This comprehensive guide explores why engineers worldwide trust this photovoltaic output isolator for critical applications.

In-Depth Technical Analysis

Unmatched Isolation Performance

With its 5,000Vrms isolation rating, the HCNR201-000E provides superior protection against voltage transients and noise interference. The device achieves this through:

  • Advanced LED-photodiode optical coupling technology
  • Premium-grade isolation barrier materials
  • Precision 8-DIP packaging with 10.16mm creepage distance

Precision Signal Transfer

The HCNR201-000E's linearized photovoltaic output ensures minimal distortion with:

  • CTR range: 0.36% to 0.72% at 10mA
  • Typical forward voltage: 1.6V
  • Maximum DC forward current: 25mA
  • Bandwidth: 1MHz typical

Enhanced Reliability Features

Broadcom's rigorous quality control delivers:

  • Extended operating temperature range (-55 C to +100 C)
  • 50,000-hour minimum LED lifespan
  • Moisture sensitivity level (MSL): 1 (unlimited floor life)
  • RoHS compliant construction

Industry-Leading Applications

Power Systems

  • Isolated feedback in SMPS designs
  • Solar inverter monitoring
  • Battery management systems

Industrial Automation

  • PLC signal isolation
  • Motor drive feedback circuits
  • Process control instrumentation

Medical Equipment

  • Patient monitoring isolation
  • Diagnostic equipment interfaces

Competitive Advantages

The HCNR201-000E outperforms alternatives with:

  1. Superior Linearity: 0.05% typical nonlinearity
  2. Enhanced Stability: 0.1%/ C gain drift
  3. Robust Construction: 8-pin DIP withstands harsh environments
  4. Design Flexibility: Compatible with both AC and DC inputs

Implementation Guide

For optimal performance:

  • Use 10-20mA forward current for best CTR
  • Implement proper PCB layout for noise immunity
  • Include 0.1 F bypass capacitor near device
  • Follow IPC-A-610 cleanliness standards

Conclusion

The HCNR201-000E sets the benchmark for reliable signal isolation in demanding applications. Its combination of 5kV protection, precision linearity, and Broadcom's quality assurance makes it the preferred choice for engineers designing mission-critical systems. For detailed specifications, application notes, or volume pricing, contact our technical team today.